================================================================= NC-MK2 Relay revision changes ================================================================= -------------------------------------- Date : 10 March 2022 Revision : 5D has the following added: -------------------------------------- - Cooling curve model to cool down at the same rate as if the drive was running. - The cooling curve will now cool down 2 x faster when the drive is standing still. -------------------------------------- Date : 8 Sept 2020 Revision : 5C has the following added: -------------------------------------- - Added new Voltage selections. - Added Modbus/TCP and PROFINET to internal communication selection. Revision : 5A has the following added: -------------------------------------- - Communicate with the external communication module: Revision : 3F has the following added: -------------------------------------- - Added Amps, kVa and kW to output selection of 4 to 20mA. - ESTOP works with portection relay. + When the ESTOP is pressed the trip relay will go in a trip state. + If unauthorized current is set then unathorized current will also be active. Revision : 3E has the following added: -------------------------------------- - 4 to 20 mA extended features added. - Voltage above 525V readings corrected. ================================================================= NC-MK1 Relay revision changes ================================================================= 1H and higher needs the profibus module to be programmed to revision 2.00. This can only be done with NewElec aid. Revision : 2F has the following added: -------------------------------------- - Device ID and description locking frontend. Revision : 2E has the following added: -------------------------------------- - USB and IrDA communication improvement. - Stop and Interlocks are combined. - Insulation and Vacuum failure get's locked out when one of the following conditions are met: + In service flag is true or, + Feedback signal is high or, + A start command was given. Revision : 2D has the following added: -------------------------------------- - Reading of the RTD module: + PT100 and PT1000 will still read as degree C. + PTC and NTC will read as Ohms. - In service has been programmed with a switching threshold: + MLC 10% and greater will switch on at 10%. + MLC 10% and greater will switch off at 5%. + MLC 9% and smaller will switch on at 20%. + MLC 9% and smaller will switch off at 15%. Revision : 2D has the following added: -------------------------------------- - Current and voltage measurement improved. - Settings are stored with checksum. - Settings check is done with relation to the new checksum. Revision : 2B has the following added: -------------------------------------- - Corrected Unauthorized current. - Current level now showing correctly in events and faults. Revision : 2A has the following added: -------------------------------------- - Added revision of the VPC stack to the Frontend. - Added MMI-420 interface to code. Revision : 1I has the following added: -------------------------------------- - Fixed up the emergency stop feature. Revision : 1H has the following added: -------------------------------------- - RTD Type. - 4 to 20 milli amp is mapped via the profibus byte 2 and 3.